Customization: | Available |
---|---|
Type: | Surgical Supplies Materials |
Material: | Plastic |
Still deciding? Get samples of US$ 0.0/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1.Packaging
1pc per inner aluminum foil bag,
50/100 pcs per box(or per outer bag),
1000/2000/5000pcs per carton
2.Shipping
1) Small order: By express, DHL/ UPS/ Fedex/ EMS etc.
2) Large order: By sea or By air
3) Choose the best and convinient way for your need
Test must be in room temperature (10oC to 30oC)
1. Open the sealed pouch by tearing along the notch. Remove the test device from the pouch.
2. Hold the one side of the device with one hand. Use the other hand to pull out the cap and
expose the absorbent end.
3. Immerse the absorbent end into the urine sample about 10 seconds. Make sure that the urine
level is not above the "MAX" line printed on the front of the device.
4. Lay the device flat on a clean, dry, non-absorbent surface.
5. Read the result at 5 minutes. Do not read after 5 minutes.
RESULTES
Negative: Two pink-colored bands appear, one in the control region and one in the test region. A negative result indicates free drug is absent from urine or at concentrations lower than the detection cut-off level of the test.
Positive: One pink-colored band appears in the control region with no apparent band appearing in the test region with no apparent band appearing in the test region. A positive result indicates free drug is present in urine at concentrations at or exceeding the detection cut-off level of the test.
Invalid: No band appears in the control region, or a pink-colored band appears in the test region only. An invalid test result may be due to improper assay procedures or damage to the device. With an invalid result, the specimen should be re-tested using a new test.
Note: The test band intensity may be weaker or stronger than that of the control band.
Product Name | Catalog No. | Specimen | Format | Test/Kit | Cut-off(ng/mL) | |
DOA Single-Drug | AMP | DAM-101/102 | Urine | Strip/Device | 50T/40T | 1000 |
BAR | DBA-101/102 | Strip/Device | 50T/40T | 300 | ||
BZO | DBZ-101/102 | Strip/Device | 50T/40T | 300 | ||
COC | DCO-101/102 | Strip/Device | 50T/40T | 300 | ||
COT | DCT-101/102 | Strip/Device | 50T/40T | 200 | ||
EDDP | DED-101/102 | Strip/Device | 50T/40T | 300 | ||
FTY | DFT-101/102 | Strip/Device | 50T/40T | 100 | ||
KET | DKE-101/102 | Strip/Device | 50T/40T | 1000 | ||
MDMA | DMD-101/102 | Strip/Device | 50T/40T | 500 | ||
MET (MET/mAMP) |
DME-101/102 | Strip/Device | 50T/40T | 1000 | ||
MOP Morphine 300 (OPI300) |
DMO-101/102 | Strip/Device | 50T/40T | 300 | ||
MTD | DMT-101/102 | Strip/Device | 50T/40T | 300 | ||
OPI Opiate 2000 | DOP-101/102 | Strip/Device | 50T/40T | 2000 | ||
OXY | DOX-101/102 | Strip/Device | 50T/40T | 100 | ||
PCP | DPC-101/102 | Strip/Device | 50T/40T | 25 | ||
PPX | DPX-101/102 | Strip/Device | 50T/40T | 300 | ||
TCA | DTC-101/102 | Strip/Device | 50T/40T | 1000 | ||
THC Marij/ | DTH-101/102 | Strip/Device | 50T/40T | 50 | ||
TRA Tramadol | DTR-101/102 | Strip/Device | 50T/40T | 300 | ||
Description | Catalog No. | Specimen | Format | Test per Kit | ||
DOA Multi-Drug Panel/ Device/Cup |
Multi-Drug One Step Drug Screen Test Panel | DOA-124 to DOA-1124 | Urine | 2-12 Drugs | 20 Test/ box | |
DUD-124 to DUD-1124 | 2-10 Drugs | |||||
Multi-Drug One Step Multi-Line Drug Screen Test Device | DOA-125 to DOA-1124 | Urine | 2-12 Drugs | |||
Multi-Drug Panel withIntegrated E-Z Split KeyTM Cup II | DBO-127 to DBO-1127 | Urine | 2-12 Drugs | |||
DBD-127 to DBD-1107 | 2-15 Drugs | |||||
Urine Adulteration Strips (Creatinine/Nitrite/ Glutaraldehyde/ pH/Specificravity/Oxidant) |
6 parameter strip | DUC-111 | Urine | 6 parameter strip |